Friday, September 7, 2012

9/7/2012 - The impression drum temperature did not reach the desired temperature...

Case # 4681721344

HP tech: Clint.

Error message:  The impression drum temperature did not reach the desired temperature, please try again... Check and adjust the impression drum IR sensor"

You can see the impression drum IR sensor; the large coil/threaded thing that you see when you remove the air knife hose, but to clean it, you open the side bottom door, open the duplex conveyer, to the left, clean the impression drum shoulder and gear area, clean the IR sensor.

Wednesday, September 5, 2012

9/5/2012 - Perfector vacuum level too high

Perfector vacuum level too high at 0.76, should be at 0.65.

Case# 4681541895 spoke to Clint at HP.

Go to Diagnostic/substrate/Vacuum/ click the pump to see where is at.

Go to the back of the press, open the oily waste door, adjust the knob that has the spring, turn counter clock wise  1/4 turn at a time.