10/29/2012 - White banding

Again, we got this white 1/2" white banding near the leading edge of the prints.  It happens to every other sheet.  Usually changing the PIP will resolve the issue, however, our PIP didn't get the HP suggested impression count and started showing the band.  This time around 4000 impressions only.

Solution:
1. open the back of the press, near the turning wheel, you see a black screw cap that covers a wire.  Unscrew the black screw cover, take out the spring wire thing, clean the rectangular shaped copper block attached to the spring with IPA.  Use a cotton swab with IPA and clean the hole while turning the itm wheel. Put everything when finished.

2. Run auto bias.

3. Be sure the tray that is below the cleaning station is sturdy, not moving.  If not sturdy, screw it tight.


2 comments:

  1. This comment has been removed by the author.

    ReplyDelete
  2. Are you having trouble in Blockchain account? Is the Blockchain two-factor authentication creating trouble for you and unable to work? If you don’t know how to deal with issues and troubles, you can directly contact with the team who is always functional and users can have conversation with the team anytime for availing quality results. You can talk to the team and get verified solutions via Blockchain phone number (833) 993-0690 which are easy to execute and users can talk to them for availing qualified and verified results in no time.